In statistics, the Anscombe transform, named after Francis Anscombe, is a variance-stabilizing transformation that transforms a random variable with a Poisson distribution into one with an approximately standard Gaussian distribution. The Anscombe transform is widely used in photon-limited imaging (astronomy, X-ray) where images naturally follow the Poisson law. The Anscombe transform is usually used to pre-process the data in order to make the standard deviation approximately constant. Then denoising algorithms designed for the framework of additive white Gaussian noise are used; the final estimate is then obtained by applying an inverse Anscombe transformation to the denoised data.

Definition
For the Poisson distribution the mean



m


{\displaystyle m}

and variance



v


{\displaystyle v}

are not independent:



m
=
v


{\displaystyle m=v}

. The Anscombe transform

A
:
x
↦
2


x
+



3
8








{\displaystyle A:x\mapsto 2{\sqrt {x+{\tfrac {3}{8}}}}\,}

aims at transforming the data so that the variance is set approximately 1 for large enough mean; for mean zero, the variance is still zero.
It transforms Poissonian data



x


{\displaystyle x}

(with mean



m


{\displaystyle m}

) to approximately Gaussian data of mean



2


m
+



3
8





−



1

4


m

1

/

2






+
O

(



1

m

3

/

2





)



{\displaystyle 2{\sqrt {m+{\tfrac {3}{8}}}}-{\tfrac {1}{4\,m^{1/2}}}+O\left({\tfrac {1}{m^{3/2}}}\right)}


and standard deviation



1
+
O

(



1

m

2





)



{\displaystyle 1+O\left({\tfrac {1}{m^{2}}}\right)}

.
This approximation gets more accurate for larger



m


{\displaystyle m}

, as can be also seen in the figure.
For a transformed variable of the form



2


x
+
c




{\displaystyle 2{\sqrt {x+c}}}

, the expression for the variance has an additional term









3
8



−
c

m




{\displaystyle {\frac {{\tfrac {3}{8}}-c}{m}}}

; it is reduced to zero at



c
=



3
8





{\displaystyle c={\tfrac {3}{8}}}

, which is exactly the reason why this value was picked.

Inversion
When the Anscombe transform is used in denoising (i.e. when the goal is to obtain from



x


{\displaystyle x}

an estimate of



m


{\displaystyle m}

), its inverse transform is also needed
in order to return the variance-stabilized and denoised data



y


{\displaystyle y}

to the original range.
Applying the algebraic inverse

A

−
1


:
y
↦


(


y
2


)


2


−


3
8




{\displaystyle A^{-1}:y\mapsto \left({\frac {y}{2}}\right)^{2}-{\frac {3}{8}}}

usually introduces undesired bias to the estimate of the mean



m


{\displaystyle m}

, because the forward square-root
transform is not linear. Sometimes using the asymptotically unbiased inverse

y
↦


(


y
2


)


2


−


1
8




{\displaystyle y\mapsto \left({\frac {y}{2}}\right)^{2}-{\frac {1}{8}}}

mitigates the issue of bias, but this is not the case in photon-limited imaging, for which
the exact unbiased inverse given by the implicit mapping

m

x



e

−
m




x
!




)

↦
m


{\displaystyle \operatorname {E} \left[2{\sqrt {x+{\tfrac {3}{8}}}}\mid m\right]=2\sum _{x=0}^{+\infty }\left({\sqrt {x+{\tfrac {3}{8}}}}\cdot {\frac {m^{x}e^{-m}}{x!}}\right)\mapsto m}

should be used. A closed-form approximation of this exact unbiased inverse is

y
↦


1
4



y

2


−


1
8


+


1
4





3
2




y

−
1


−


11
8



y

−
2


+


5
8





3
2




y

−
3


.


{\displaystyle y\mapsto {\frac {1}{4}}y^{2}-{\frac {1}{8}}+{\frac {1}{4}}{\sqrt {\frac {3}{2}}}y^{-1}-{\frac {11}{8}}y^{-2}+{\frac {5}{8}}{\sqrt {\frac {3}{2}}}y^{-3}.}

Alternatives
There are many other possible variance-stabilizing transformations for the Poisson distribution. Bar-Lev and Enis report a family of such transformations which includes the Anscombe transform. Another member of the family is the Freeman-Tukey transformation

A
:
x
↦


x
+
1


+


x


.



{\displaystyle A:x\mapsto {\sqrt {x+1}}+{\sqrt {x}}.\,}

A simplified transformation, obtained as the primitive of the reciprocal of the standard deviation of the data, is

A
:
x
↦
2


x





{\displaystyle A:x\mapsto 2{\sqrt {x}}\,}

which, while it is not quite so good at stabilizing the variance, has the advantage of being more easily understood.
Indeed, from the delta method,

V
[
2


x


]
≈


(



d
(
2


m


)


d
m



)


2


V
[
x
]
=


(


1

m



)


2


m
=
1


{\displaystyle V[2{\sqrt {x}}]\approx \left({\frac {d(2{\sqrt {m}})}{dm}}\right)^{2}V[x]=\left({\frac {1}{\sqrt {m}}}\right)^{2}m=1}

.

Generalization
While the Anscombe transform is appropriate for pure Poisson data, in many applications the data presents also an additive Gaussian component. These cases are treated by a Generalized Anscombe transform and its asymptotically unbiased or exact unbiased inverses.

See also
Variance-stabilizing transformation
Box–Cox transformation

References

Further reading
Starck, J.-L.; Murtagh, F. (2001), "Astronomical image and signal processing: looking at noise, information and scale", Signal Processing Magazine, IEEE, vol. 18, no. 2, pp. 30–40, Bibcode:2001ISPM...18...30S, doi:10.1109/79.916319, S2CID 13210703